Ingersoll Rand / ARO Expert Series 2" vs. Wilden 2" (P8)
• Air pressure set at 6bar and flow rate at 6.6 metres cubed per hour
Number of cycles per minute for flow rate:
ARO = 23.16 | vs.| Wilden P8 = 30.12
Ingersoll Rand / ARO diaphragm cycle rate is 25% less to produce the same amount of flow - this results in 25% more diaphragm life on comparable duties!
• Air consumption at 6bar
ARO = 33.71 CFM | vs.| Wilden P8 = 45.84 CFM
Wilden pumps use 27% more air on comparable flow rates - on a 24/7 duty this would equate to a saving of £566 on air consumption alone (based on industry electricity costing 7p per KW/Hr) - & THIS IS PER PUMP!!